OIL TESTING KIT
It comprises of a Vacuum pump with flexible pipe, Conical flask, Funnel, Sintered Glass Membrane holder, Pincette, Metallic Clamp., 500 ml plastic Benzene bottle, 0.8 micron membrane filter paper (1 Box - 100Nos.) It is suitable for patch test for oil samples Before & After Kleenoil filtration |
|
|
|
TESTING PROCEDURE
A minimum 25 ml fluid sample is needed per analysis. A 25 mm diameter 1 or 5 micron patch membrane is placed under the fluid funnel assembly. Then a 25 ml fluid sample is placed into the funnel assembly. With the funnel assembly attached to the vacuum pump the analysis can now be performed. The vacuum pump is then actuated which pulls the fluid from the funnel through the 25 mm patch membrane filter. Use the solvent to wash the funnel of all fluid residue. Then place the patch membrane onto the included 3/5 index cards and seal the patch membrane with the included adhesive laminating seals. The laminating seals keep outside particles from contaminating the patch membrane. Then use the 100X microscope to visually see the captured particles caught by the 1 or 5 micron patch membrane filters. This visual representation can be used to determine the ISO Fluid Cleanliness Class Range. |
|||||
|
|
This
is a clean fluid sample viewed through the
100X microscope. This corresponds to an
ISO 14/12 cleanliness code.
This is a dirty fluid sample as viewed through the 100X microscope and corresponds to an ISO 17/15 cleanliness code. |
|